Site Overlay

ASTM D1622 PDF

GeoTesting Express is a provider of Geosynthetic Testing Services – ASTM D,Standard Test Method for Apparent Density of Rigid Cellular Plastics. View Abstract. Product Details. Detail Summary. View all details. Superseded By: ASTM D/DM. EN. Format. Details. Price (USD). PDF. ASTM D – Designation: D – 08 Standard Test Method for Apparent Density of Rigid.

Author: Akicage Gardabei
Country: Moldova, Republic of
Language: English (Spanish)
Genre: Personal Growth
Published (Last): 13 August 2014
Pages: 403
PDF File Size: 8.63 Mb
ePub File Size: 13.83 Mb
ISBN: 296-3-59563-633-2
Downloads: 18646
Price: Free* [*Free Regsitration Required]
Uploader: Kajikazahn

A number in parentheses indicates the year of last reapproval. This standard has been approved for use by agencies of the Department of Defense. Density can be evaluated as the apparent overall density includes forming skins or by apparent core density forming skins removed.

The values given in parentheses are for information only. It is the responsibility of the user of this standard asgm establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

If the material does not have forming skins, the term overall density is not applicable. Any test specimen preparation, conditioning, dimensions, or testing parameters, or combination thereof, covered in the relevant ASTM materials speci?

If there are no relevant ASTM material speci? In this case, the test specimen d1262 the entire sample. Current edition approved April 1, Originally approved in Last previous edition approved in as D – Spray equipment shall be adjusted to the best spray pattern and optimum performance.

Spray apply a minimum 1. After a minimum of 5 min, spray apply a second layer of 3. For calculation of core density, remove the bottom layer and the top skin. For calculation s1622 the apparent overall density, cut a specimen that includes the forming skin. The specimens shall be taken from locations distributed throughout the sample.

  HYDROCHIMIE COURS PDF

Number of Specimens 8. Hold the pressure of the dial foot to 2.

In these cases the pressure shall be reduced accordingly. When a sliding caliper gage is used, the proper setting shall be that point at which the measuring faces of the gage contact the surfaces of the specimen without compressing them. Do not use a steel rule for dimensions less than 25 mm 1 in. Measure all dimensions to a precision of In general, three measurements shall be made of each dimension.

Standard – Standard Test Method for Apparent Density of Rigid Cellular Plastics ASTM D –

A lesser number may be made when the following conditions apply: Measurements per Dimension 1 2 NOTE 3—The air buoyancy effect will vary with time and depends on the open-cell content of the foam.

Highly open-celled materials are essentially air-? However, freshly produced closed-cell materials are sstm air-void and will exhibit maximum buoyant effects of air. SR is the between-laboratories standard deviation of the average. VR r1622 the between-laboratories coefficient of variation of the average.

Standard Test Method for Apparent Density of Rigid Cellular Plastics

Precision and Bias4 For each material, all the samples were prepared at one source, but the individual specimens were prepared at the laboratories that tested them.

Each test result was the average of? Each laboratory obtained one test result for each material. Users of this test method should apply the principles outlined in Practice E to generate data speci? The principles of There are no recognized standards on which to base an estimate of bias for this test method.

  GRAMATICA PRACTICA A LIMBII ROMANE STEFANIA POPESCU PDF

Active Risk Management

Thus, the value of Wa is zero in the above calculation when the sample is at equilibrium with the air. In this case the calculation for density is identical to the calculation in April 1, 1 Added new 1. Revised Average value for Material 3 in Table 1. Revised Material 4 repeatability interval, Ir. Revised Average value for Material 3 in Table 2. ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard.

Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every? Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend.

If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below. Individual reprints single or multiple copies of this standard may be obtained by contacting ASTM at the above address or at phonefaxor service astm.